Products‎ > ‎Solar System‎ > ‎Off Grid Solar Inverter‎ > ‎

PV1800 PK PWM Series (1-5KVA)

                                                                     
   

High Frequency Off Grid Solar Inverter

PV1800 PK PWM Series (1-5KVA)

This is a multi-function inverter/charger, combining functions of inverter, 

PWM solar charger and battery charger to offer uninterruptible power support with portable size. 

Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, 

AC/solar charger priority, and acceptable input voltage based on different applications.

Overview


Features






SPECIFICATION

MODELPV18-1K PKPV18-2K PKPV18-3K PKPV18-4K PKPV18-5K PK
Default Battery System Voltage12VDC24VDC24VDC48VDC48VDC
INVERTER OUTPUTRated Power1000VA2000VA3000VA4000VA5000VA
800W1600W2400W3200W4000W
Surge Power2000VA4000VA6000VA8000VA10000VA
WaveformPure sine wave
AC Voltage Regulation (Batt.Mode)230VAC±5%
Inverter Efficiency (Peak)90%93%
Transfer Time10ms(For Personal Computers)
20ms(For Home Appliances)
AC INPUTVoltage230VAC
Selectable Voltage Range170~280VAC(For Personal Computers)
90~280VAC(For Home Appliances)
Frequency Range50Hz/60Hz (Auto sensing)
BATTERYNominal voltage12VDC24VDC48VDC
Floating Charge Voltage13.5VDC27VDC54VDC
Overcharge Protection15.5VDC31VDC60VDC
SOLAR CHARGER
&
AC CHARGER
Maximum PV Array Open Circuit Voltage50VDC60VDC105VDC
Standby Power Consumption1W2W2W
(PWM)Maximum Solar Charge Current50A
Maximum AC Charge Current10A or 20A20A or 30A60A
Maximum Charge Current50A50A110A
MECHANICAL SPECIFICATIONDimension,W*H*D240*316*95mm272*355*100mm297.5*468*125mm
Net Weight (kg)81215
OTHERHumidity5% to 95% Relative Humidity (Non-condensing)
Operating Temperature0°C -55°C
Storage Temperature-15°C -60°C
Loading(20GP/40GP/40HQ)570pcs / 1150pcs  /  1380 pcs360pcs  /  720pcs   /    850pcs

APPROXIMATE BACK-UP TIME TABLE

ModelLoad(VA)Backup Time@48V 100Ah(min)Backup Time@48V 200Ah(min)
4KVA4007661610
2000112269
400050112
5KVA5006131288
250090215
50004090
ModelLoad(VA)Backup Time@12V 100Ah(min)Backup Time@12V 200Ah(min)
1KVA1007661610
60095227
100050112
ModelLoad(VA)Backup Time@24V 100Ah(min)Backup Time@24V 200Ah(min)
2KVA2007661610
1000112269
200050112
3KVA3004491100
150068164
30002867